titleVoghion Online Shop Logo
Voghion: Explore, Shop, Enjoy
99€ coupons for app users
GET
Open All Categories Menu
Voghion Logo
Your AccountShopping Cart
Search Bar Submit Button
SpO2 Simulator MS100 Pulse Rate Blood Oxygen Simulator Pulse Oximeter Reaction Time_voghion.com
SpO2 Simulator MS100 Pulse Rate Blood Oxygen Simulator Pulse Oximeter Reaction Time_voghion.com
SpO2 Simulator MS100 Pulse Rate Blood Oxygen Simulator Pulse Oximeter Reaction Time_voghion.com
SpO2 Simulator MS100 Pulse Rate Blood Oxygen Simulator Pulse Oximeter Reaction Time_voghion.com
SpO2 Simulator MS100 Pulse Rate Blood Oxygen Simulator Pulse Oximeter Reaction Time_voghion.com
SpO2 Simulator MS100 Pulse Rate Blood Oxygen Simulator Pulse Oximeter Reaction Time_voghion.com
1/6
Buy now pay later

SpO2 Simulator MS100 Pulse Rate Blood Oxygen Simulator Pulse Oximeter Reaction Time

672.35
946.98
-29%
2928.67-292.87
2341.76-234.29
1521.74-152.29
1041.44-105.43
ItemNo: 30402407
model
ms100
Free Shipping via Free Local Deliver
Arrives in 3~7 business days
Buyer Protection
ltem description from the seller
Specification Available Ship to:United States Details Introduction This device is a separated SpO2 simulator which features in small volume and light weight. It can perform a series of tests by the simulation means, to provide an accurate reference for the Pulse Oximeter. As different manufacturers may use different R-curve, current popular R curves (such as BCI, Masimo, Nellcor, etc.) are embedded into the simulator in advance. Function 1)Simulation of SpO2 and pulse rate. 2)Support SpO2 and pulse rate simulation under 60 Hz/50 Hz interference and light interference. 3)Adjustable perfusion index (PI), support SpO2 and pulse rate simulation under different PI. 4)The reaction time of SpO2, PR and cardiac arrest can be tested. 5)Built-in 10 compatible R curves (such as BCI, Masimo, Nellcor, etc.), meet the test requirements (R curve can be customized). 6)Preset 24 patient states, such as weak pulse, bradycardia, hypoxia, infant, tachycardia, the aged, obesity, etc. Main parameters 1)SpO2 Range: 35 % ~ 100 % Resolution: 1 % Accuracy: when SpO2 is 75 % ~ 100 %, the error is ± 2 % or ± the device's accuracy, whichever is greater; when SpO2 is 74 % ~ 50 %, the error is ± 3 % or ± the device's accuracy, whichever is greater; no definition when SpO2 is less than 50 %. 2)Pulse rate Range: 20 bpm ~ 250 bpm Resolution: 5 bpm Accuracy: 1 % ± 1 bpm 3)Low perfusion Range: 0.000 % ~ 20.000 % Resolution: 1.000 % ~ 20.000: 1 % 0.100 % ~ 0.900 %: 0.1 % 0.000 ~ 0.075 %: 0.025 % 4)Patient state Preset 24 group of states, the default is 8 groups, and it can be adjusted by setting the motion level. 5)Battery A 3.7 V rechargeable lithium battery Accessories A User Manual A simulator finger (MS100-SP) An adapter (5.0 V) Physical characteristic Dimension: 189 (L) × 125 (W) × 56 (H) mm (including bracket) Weigh: about 600 g (including a lithium battery)
View More